Eksperimental Tata Letak Baut Pada Sambungan Momen Di Struktural ColdFormed Steel

Mursyid, Aji Maulana (2010) Eksperimental Tata Letak Baut Pada Sambungan Momen Di Struktural ColdFormed Steel. Other thesis, Universitas Komputer Indonesia.

[thumbnail of 01. UNIKOM_AJI_COVER.pdf] Text
01. UNIKOM_AJI_COVER.pdf

Download (30kB)
[thumbnail of 02. UNIKOM_AJI_ABSTRAK.pdf] Text
02. UNIKOM_AJI_ABSTRAK.pdf

Download (13kB)
[thumbnail of 03. UNIKOM_AJI_KATA PENGANTAR.pdf] Text
03. UNIKOM_AJI_KATA PENGANTAR.pdf

Download (24kB)
[thumbnail of 04. UNIKOM_AJI_DAFTAR ISI.pdf] Text
04. UNIKOM_AJI_DAFTAR ISI.pdf

Download (48kB)
[thumbnail of 06. UNIKOM_AJI_DAFTAR GRAFIK.pdf] Text
06. UNIKOM_AJI_DAFTAR GRAFIK.pdf

Download (16kB)
[thumbnail of 08. UNIKOM_AJI_BAB 1.pdf] Text
08. UNIKOM_AJI_BAB 1.pdf

Download (32kB)
[thumbnail of 09. UNIKOM_AJI_BAB 2.pdf] Text
09. UNIKOM_AJI_BAB 2.pdf

Download (222kB)
[thumbnail of 10. UNIKOM_AJI_BAB 3.pdf] Text
10. UNIKOM_AJI_BAB 3.pdf

Download (105kB)
[thumbnail of 11. UNIKOM_AJI_BAB 4.pdf] Text
11. UNIKOM_AJI_BAB 4.pdf

Download (5MB)
[thumbnail of 12. UNIKOM_AJI_BAB 5.pdf] Text
12. UNIKOM_AJI_BAB 5.pdf

Download (41kB)
[thumbnail of 13. UNIKOM_AJI_DAFTAR PUSTAKA.pdf] Text
13. UNIKOM_AJI_DAFTAR PUSTAKA.pdf

Download (68kB)

Abstract

Sambungan momen pada cold-formed adalah sambungan yang menahan gaya

momen yang bekerja pada cold-formed. Sambungan ini umumnya menggunakan

lebih dari 1 baut/sekrup. Sambungan coldform didesain berdasarkan peraturan

LRFD (Load and Resistance Factor Design) dan peraturan AISI 2001.

Perhitungan sambungan baja coldform menggunakan pembebanan sebidang.

Umumnya disambungan momen jumlah baut pada sambungan tidak berpengaruh,

karena pada sambungan cold formed lebih ditentukan pada ketebalan cold formed

tersebut. Dan eksentrisitas pada sambungan dari tata letak baut akan menentukan

hasil kekuatan pada sambungan tersebut.

Moment connections in cold-formed is a connection that holds the force moments

acting on the cold-formed. These connections typically use more than one bolt /

screw. Connections are designed based on the rules coldform LRFD (Load and

Resistance Factor Design) and the rules of AISI 2001. Calculation of steel

connections using the loading plot coldform. Generally, the number of bolts on the

connection moment connection is not affected because of the cold formed

connections more determined on the thickness of cold formed. And eccentricity at

the connection of bolt layout will determine the outcome of the strength of the

connection.

Item Type: Thesis (Other)
Additional Information: Migrasi dari GDL. Identifier: jbptunikompp-gdl-ajimaulana-22629. Folder: S1-Final_Project / Fakultas_Teknik_dan_Ilmu_Komputer / Teknik_Sipil / 2010
Uncontrolled Keywords: Sambungan Baja, Coldform, Baut Hitam
Divisions: S1 Skripsi > Teknik Sipil
Depositing User: Robot Migration
Date Deposited: 05 Nov 2026 07:33
Last Modified: 05 Nov 2026 07:33
URI: https://elibrary.unikom.ac.id/id/eprint/33788

Actions (login required)

View Item
View Item