Asali, Frans Fernando (2015) Analisis Dan Perancangan Data Center Dengan Pendekatan Standarisasi TIA-942 Di PUSLITBANG Sumber Daya Air (PUSAIR) Bandung. Other thesis, Universitas Komputer Indonesia.
UNIKOM_FRANS FERNANDO ASALI_BAB I.pdf
Download (197kB)
UNIKOM_FRANS FERNANDO ASALI_BAB II.pdf
Download (1MB)
UNIKOM_FRANS FERNANDO ASALI_BAB III.pdf
Download (2MB)
UNIKOM_FRANS FERNANDO ASALI_BAB IV.pdf
Download (584kB)
UNIKOM_FRANS FERNANDO ASALI_BAB V.pdf
Download (11kB)
UNIKOM_FRANS FERNANDO ASALI_COVER.pdf
Download (55kB)
UNIKOM_FRANS FERNANDO ASALI_DAFTAR ISI.pdf
Download (117kB)
UNIKOM_FRANS FERNANDO ASALI_DAFTAR PUSTAKA.pdf
Download (54kB)
UNIKOM_FRANS FERNANDO ASALI_KATA PENGANTAR.pdf
Download (69kB)
UNIKOM_FRANS FERNANDO ASALI_LEMBAR PENGESAHAN.pdf
Download (125kB)
UNIKOM_FRANS FERNANDO ASALI_SURAT HAK EKSKLUSIF.pdf
Download (125kB)
UNIKOM_FRANS FERNANDO ASALI_SURAT PERNYATAAN TIDAK PLAGIAT.pdf
Download (273kB)
Abstract
Pusat Penelitian dan Pengembangan Sumber Daya Air (PUSAIR) Bandung adalah salah satu litbang yang memperhatikan penggunaan teknologi informasi (TI). Pusair memiliki divisi IT dan resource yang diletakan pada suatu tempat yang disebut dengan data center. Data center pusair saat ini memiliki ukuran luas computer room yang kecil, konstruksi ruang yang belum ideal, pelabelan dan dokumentasi yang belum baik, serta server yang kadang mengalami restart. Akibat dari kondisi tersebut membuat proses kegiatan penelitian pusair menjadi terganggu. Berdasarkan masalah-masalah di atas, maka untuk mengatasinya perlu dilakukan standarisasi data center, sehingga terbentuk kriteria data center yang baik, yaitu availability, scalability/flexibility dan security. Dalam melakukan penelitian menggunakan metode gap analysis sebagai acuan dan TIA-942 sebagai standar untuk perancangan data center. Adapun hasil dari penelitian ini, yaitu menghasilkan dokumentasi keseluruhan terhadap kondisi infrastruktur data center eksisting, menghasilkan perbandingan antara kondisi eksisting, kondisi desain terhadap kondisi TIA tier 1 dan menghasilkan desain/rancangan data center berdasarkan pendekatan TIA tier 1.
Pusat Penelitian and Pengembangan Sumber Daya Air (PUSAIR) Bandung is one of research and development that regards to the use of information technology (TI). PUSAIR is has an IT division and resource that placed on a space called data center. Data center PUSAIR recently is has a broad measure of computer room which is small. Then, the construction space is not ideal, labeling and documentation are not good, as well as the server is sometime experiencing a restart. As a result of the condition makes a process of research activities in PUSAIR disturbed. Based on the problem above, to resolve the problem has to do the standardization of data center. So that it will be able to form the good criteria of data center, such as availability, scalability/flexibility and security. In doing this research, the researcher uses gap analysis method as a reference and TIA-942 as a standard to design of data center. As for the result of the research, this research produces overall documentation to infrastucture condition that existing, comparison between the exsisting condition, design condition to TIA tier 1 and produces design of data center that appropriate with the TIA tier 1.
| Item Type: | Thesis (Other) |
|---|---|
| Additional Information: | Migrasi dari GDL. Identifier: jbptunikompp-gdl-fransferna-35091. Folder: S1-Final_Project / Fakultas_Teknik_dan_Ilmu_Komputer / Teknik_Informatika / 2015 |
| Uncontrolled Keywords: | Data Center, Jaringan, Server, TIA-942, Gap Analysis |
| Divisions: | S1 Skripsi > Teknik Informatika |
| Depositing User: | Robot Migration |
| Date Deposited: | 05 Nov 2026 04:34 |
| Last Modified: | 05 Nov 2026 04:34 |
| URI: | https://elibrary.unikom.ac.id/id/eprint/21016 |